VR 60 Maximum Operating Pressures |
|
|
| Max. operating pressure 1) (psi) at medium |
Temperature (°F) |
Thickness(inch) |
Water, steam, aqueous solutions |
Gases |
Oils, greases |
Fuels, solvents |
| –1482) |
0.0394 |
- |
- |
580 |
- |
| 0.0787 |
- |
- |
363 |
- |
| 0.1181 |
- |
- |
232 |
- |
| –58 |
0.0394 |
580 |
363 |
725 |
363 |
| 0.0787 |
363 |
232 |
435 |
232 |
| 0.1181 |
232 |
145 |
290 |
145 |
| 32 |
0.0394 |
928 |
580 |
928 |
580 |
| 0.0787 |
725 |
435 |
725 |
363 |
| 0.1181 |
435 |
290 |
435 |
232 |
| 122 |
0.0394 |
928 |
580 |
928 |
580 |
| 0.0787 |
725 |
435 |
725 |
363 |
| 0.1181 |
435 |
290 |
435 |
232 |
| 212 |
0.0394 |
580 |
435 |
725 |
363 |
| 0.0787 |
363 |
363 |
580 |
232 |
| 0.1181 |
232 |
232 |
363 |
145 |
| 302 |
0.0394 |
377 |
363 |
580 |
290 |
| 0.0787 |
145 |
290 |
363 |
232 |
| 0.1181 |
87 |
145 |
232 |
145 |
| 392 |
0.0394 |
- |
- |
232 |
- |
| 0.0787 |
- |
- |
145 |
- |
| 0.1181 |
- |
- |
87 |
- |
|
 |
The data quoted above are valid for the material "as delivered" without any additional treatment and with sufficient surface pressure, e.g. according to DIN 28 090ff. In view of the multiplicity of possible gasket designs as well as installation and operating conditions, definitive conclusions cannot be drawn for all applications regarding the behavious in a sealing joint. For this reason, we do not give any warranty for technical data. They do not represent warranted properties. If you have any doubt, please contact us and specify exact operating conditions. |
| 1) |
Very much higher pressure values are possibly permitted for flanges with projections and recesses or grooves and tongues. Please consult us in individual cases, specifying exact sealing conditions. |
| 2) |
Use at temperatures below –58 °F (-50 °C) is possible when surface pressure does not drop below approx. 2180 psi (15 N/mm²) in liquids or 4350 psi (30 N/mm²) in gases (internal pressure must be considered). In addition, the gasket must not show bending stress or reversed bending stress. At temperatures below -148 °F (–100 °C), operating pressures may not be greater than the max. values given for -148 °F (–100 °C). |
|
|
Observe the Chemical Resistance in the media table "About the chemical resistance of VR 60" |
|
 |
|
 |
|
 |
|
 |
|
ISO 9001:2008
JUST IN TIME, KANBAN, DOCK TO STOCK, SPECIAL PACKAGING, DROP SHIPMENTS...
CAN SUPPLY WHAT YOU NEED, WHEN YOU NEED IT
3239 South 51st. Avenue, Cicero, Illinois 60804
Phone: 708-780-9000 • Fax: 708-780-9009
sales@afgco.comTerms and Conditions